Stationary Phase | Phase Type | Ultra-Fast (Yes/No) | T Max (oC) | Targeted Applications | EPA Method | USP Classification | Applications | Buy Now |
---|---|---|---|---|---|---|---|---|
HI-10 | 100% Cyanopropyl Polysiloxane | Yes | 260 | cis/trans FAMEs isomers analysis | 613, 1613, 8290B | G5, G8, G48 | View | Buy |
HI-50 | 50% Cyanopropyl, 50% Methyl Polysiloxane | Yes | 260 | Carbohydrates, sterols, FAMEs, favor compounds | – | G8 | – | Buy |
HI-ACID (FFAP) | Acid modified Polyethylene Glycol (PEG) | Yes | 260 | Ideal for free acids, FAMEs, BTEX aromatics, favor compounds, alcohols, spirits, polar compounds | – | – | View | Buy |
HI-FFAP EXT | Acid modified Polyethylene Glycol (PEG) | Yes | 260 | Ideal for free acids, FAMEs, BTEX aromatics, favor compounds, alcohols, spirits, polar compounds | 8032 | G14, G15, G16, G25, G35, G39 | View | Buy |
HI-PLUS 75 | Copolymer 75% Polyethylene glycol (PEG), 25% Methyl Polysiloxane | Yes | – | Alternate Selectivity High Polar column | 505 | – | – | Buy |
HI-PLUS 90 | Copolymer 90% Polyethylene glycol (PEG), 10% Methyl Polysiloxane | Yes | – | Alternate Selectivity High Polar column | 505 | – | – | Buy |
HI-TCEP | 1,2,3-tris-(2-cyanoethoxy)propane | No | 150 | ideal for aromatics and oxygenates in gasoline | – | – | – | Buy |
HI-WAX | Polyethylene Glycol (PEG) | Yes | 250 | FAMEs, flavor compounds, essential oils, BTEX aromatics, solvents, alcohols | 602, 603, 619, 8015C | G14, G15, G16, 467 (OVIs) | View | Buy |
HI-WAX BA | Polyethylene Glycol (PEG) | Yes | 250 | WAX column for Basic Compounds | 602, 603, 619, 8015C | G14, G15, G16, 467 (OVIs) | – | Buy |
HI-WAX Plus (NEW) | Polyethylene Glycol (PEG) | Yes | 250 | Highly Stable Inert PEG Phase designed for FAMEs, flavor compounds, essential oils, BTEX aromatics, solvents, alcohols | 602, 603, 619, 8015C | G14, G15, G16, 467 (OVIs) | – | Buy |
HI-WAX Spirit | Polyethylene Glycol (PEG) | No | 250 | WAX column designed for Spirits Analysis | 602, 603, 619, 8015C | G14, G15, G16, 467 (OVIs) | – | Buy |
HI-ALC 2 (NEW) | Proprietary | No | 280 | Blood Alcohol Analysis (Alternative selectivity) | – | – | View | Buy |
HI-Biodiesel 103 (NEW) | Proprietary | No | 380 | Free and total glycerine, FAMEs in biodiesel analysis, method specific | EN 14105, EN 14103, EN 14110, EN 14331 ASTM 6584 |
– | View | Buy |
HI-Biodiesel 110 (NEW) | Proprietary | No | 380 | Free and total glycerine, FAMEs in biodiesel analysis method specific | EN 14105, EN 14103, EN 14110, EN 14331 ASTM 6584 |
– | – | Buy |
HI-LAP (NEW) | Proprietary | No | 370 | Lipid analysis phase, suitable for Saturated and Unsaturated Triglycerides, Sterols and Lipids | – | – | View | Buy |
HI-PAH 2 (NEW) | Proprietary | No | 350 | Polycyclic Aromatic Hydrocarbons (PAH) – EU method | EPA 610, EPA 8100 | – | – | Buy |
HI-Solve 1 (NEW) | Proprietary | No | – | Complex solvent mixtures | – | – | View | Buy |
HI-Solve 2 (NEW) | Proprietary | No | – | Complex solvent mixtures and suitable for aromatic and oxygenates in gasoline | – | – | – | Buy |
Features and Benefits:
- Highly polar phases designed for the analysis of very polar analytes.
- Phases used for additional selectivity for polar compounds
- Crossbond technology allows column rinsing to increase column lifetime
Dimensions Available:
- Column Lengths: 10, 15, 20, 25, 30, 40, 50, 60, 75, 100, 105 m
- Column IDs: 0.18, 0.20, 0.25, 0.32, 0.53 mm
- Film Thicknesses: 0.10, 0.18, 0.20, 0.25, 0.40, 0.44, 0.50, 0.51, 1.00, 1.50 µm
Columns With Integrated Retention Gap:
- Column Lengths (+ gap): 15 + 5, 30 + 5, 60 + 5 m
- Column IDs: 0.25, 0.53 mm
- Film Thicknesses: 0.10, 0.25 µm
Ultra-Fast GC Columns:
- Column Lengths: 2.5, 5, 10, 15, 20, 30 m
- Column IDs: 0.05, 0.10, 0.15, 0.18, 0.20 mm
- Film Thicknesses: 0.05, 0.10, 0.15, 0.20, 0.40 µm
Note: All phases may not be suitable for all film thicknesses. And all combinations of dimensions may not be possible but where a combination is not available as a standard offering, please contact us directly for a custom request for your separation needs.