Stationary Phase Phase Type Ultra-Fast (Yes/No) T Max (oC) Targeted Applications EPA Method USP Classification Applications Buy Now
HI-10 100% Cyanopropyl Polysiloxane Yes 260 cis/trans FAMEs isomers analysis 613, 1613, 8290B G5, G8, G48 View Buy
HI-50 50% Cyanopropyl, 50% Methyl Polysiloxane Yes 260 Carbohydrates, sterols, FAMEs, favor compounds G8 Buy
HI-ACID (FFAP) Acid modified Polyethylene Glycol (PEG) Yes 260 Ideal for free acids, FAMEs, BTEX aromatics, favor compounds, alcohols, spirits, polar compounds View Buy
HI-FFAP EXT Acid modified Polyethylene Glycol (PEG) Yes 260 Ideal for free acids, FAMEs, BTEX aromatics, favor compounds, alcohols, spirits, polar compounds 8032 G14, G15, G16, G25, G35, G39 View Buy
HI-PLUS 75 Copolymer 75% Polyethylene glycol (PEG), 25% Methyl Polysiloxane Yes Alternate Selectivity High Polar column 505 Buy
HI-PLUS 90 Copolymer 90% Polyethylene glycol (PEG), 10% Methyl Polysiloxane Yes Alternate Selectivity High Polar column 505 Buy
HI-TCEP 1,2,3-tris-(2-cyanoethoxy)propane No 150 ideal for aromatics and oxygenates in gasoline Buy
HI-WAX Polyethylene Glycol (PEG) Yes 250 FAMEs, flavor compounds, essential oils, BTEX aromatics, solvents, alcohols 602, 603, 619, 8015C G14, G15, G16, 467 (OVIs) View Buy
HI-WAX BA Polyethylene Glycol (PEG) Yes 250 WAX column for Basic Compounds 602, 603, 619, 8015C G14, G15, G16, 467 (OVIs) Buy
HI-WAX Plus (NEW) Polyethylene Glycol (PEG) Yes 250 Highly Stable Inert PEG Phase designed for FAMEs, flavor compounds, essential oils, BTEX aromatics, solvents, alcohols 602, 603, 619, 8015C G14, G15, G16, 467 (OVIs) Buy
HI-WAX Spirit Polyethylene Glycol (PEG) No 250 WAX column designed for Spirits Analysis 602, 603, 619, 8015C G14, G15, G16, 467 (OVIs) Buy
HI-ALC 2 (NEW) Proprietary No 280 Blood Alcohol Analysis (Alternative selectivity) View Buy
HI-Biodiesel 103 (NEW) Proprietary No 380 Free and total glycerine, FAMEs in biodiesel analysis, method specific EN 14105, EN 14103, EN 14110, EN 14331
ASTM 6584
View Buy
HI-Biodiesel 110 (NEW) Proprietary No 380 Free and total glycerine, FAMEs in biodiesel analysis method specific EN 14105, EN 14103, EN 14110, EN 14331
ASTM 6584
Buy
HI-LAP (NEW) Proprietary No 370 Lipid analysis phase, suitable for Saturated and Unsaturated Triglycerides, Sterols and Lipids View Buy
HI-PAH 2 (NEW) Proprietary No 350 Polycyclic Aromatic Hydrocarbons (PAH) – EU method EPA 610, EPA 8100 Buy
HI-Solve 1 (NEW) Proprietary No Complex solvent mixtures View Buy
HI-Solve 2 (NEW) Proprietary No Complex solvent mixtures and suitable for aromatic and oxygenates in gasoline Buy

Features and Benefits:

  • Highly polar phases designed for the analysis of very polar analytes.
  • Phases used for additional selectivity for polar compounds
  • Crossbond technology allows column rinsing to increase column lifetime

Dimensions Available:

  • Column Lengths: 10, 15, 20, 25, 30, 40, 50, 60, 75, 100, 105 m
  • Column IDs: 0.18, 0.20, 0.25, 0.32, 0.53 mm
  • Film Thicknesses: 0.10, 0.18, 0.20, 0.25, 0.40, 0.44, 0.50, 0.51, 1.00, 1.50 µm

Columns With Integrated Retention Gap:

  • Column Lengths (+ gap): 15 + 5, 30 + 5, 60 + 5 m
  • Column IDs: 0.25, 0.53 mm
  • Film Thicknesses: 0.10, 0.25 µm

Ultra-Fast GC Columns:

  • Column Lengths: 2.5, 5, 10, 15, 20, 30 m
  • Column IDs: 0.05, 0.10, 0.15, 0.18, 0.20 mm
  • Film Thicknesses: 0.05, 0.10, 0.15, 0.20, 0.40 µm

Note: All phases may not be suitable for all film thicknesses. And all combinations of dimensions may not be possible but where a combination is not available as a standard offering, please contact us directly for a custom request for your separation needs.